07.02.02 Thermal relay RTI
RTI thermal electrical relay is designed for protecting electric motors from overload, phase unbalance, overcrank condition and rotor jamming. It is installed directly onto KTI and KMI AC contactors. To ensure shortcircuit protection, the unit should be supplied with fuses and modular circuit breakers intended for the correspondent value of rated actuating current. Correspond to the requirements EN 60947-1, EN 60947-4-1, EN 60947-5-1.
Sorting: article name
Total: 28 Go to page: 1 2 3
Thermal electrical relay RTI-1301 0,1-0,16 A IEK
Article: DRT10-D001-C016
Adjustable current range: 0,1-0,16 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 0,25 A
Thermal electrical relay RTI-1302 0,16-0,25 A IEK
Article: DRT10-C016-C025
Adjustable current range: 0,16-0,25 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 0,5 A
Thermal electrical relay RTI-1303 0,25-0,4 A IEK
Article: DRT10-C025-D004
Adjustable current range: 0,25-0,4 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 1 A
Thermal electrical relay RTI-1304 0,4-0,63 A IEK
Article: DRT10-D004-C063
Adjustable current range: 0,4-0,63 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 1 A
Thermal electrical relay RTI-1305 0,63-1,0 A IEK
Article: DRT10-C063-0001
Adjustable current range: 0,63-1,0 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 2 A
Thermal electrical relay RTI-1306 1-1,6A IEK
Article: DRT10-0001-D016
Adjustable current range: 1-1,6 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 2 A
Thermal electrical relay RTI-1307 1,6-2,5 A IEK
Article: DRT10-D016-D025
Adjustable current range: 1,6-2,5 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 4 A
Thermal electrical relay RTI-1308 2,5-4,0 A IEK
Article: DRT10-D025-0004
Adjustable current range: 2,5-4,0 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 6 A
Thermal electrical relay RTI-1310 4-6A IEK
Article: DRT10-0004-0006
Adjustable current range: 4-6 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 8 A
Thermal electrical relay RTI-1312 5,5-8A IEK
Article: DRT10-D055-0008
Adjustable current range: 5,5-8 A
Number of auxiliary contacts as normally closed contact: 1
Number of auxiliary contacts as normally open contact: 1
Ток предохранителя aM: 12 A
Total: 28
1 2 3
Search by parameters
Adjustable current range A
Ток предохранителя aM A
Ток предохранителя qG A
Nominal rated voltage V
Rated insulation voltage Ui V
Rated surge voltage kV
Tightening moment Nm
Макс момент затяжки зажимов главн цепи Nm
Доп конт - Момент затяжки Nm
Ambient temperature °C
Сечение присоед гибкого каб без наконечника mm²
Сечение присоед гибкого каб с наконечником mm²
Width mm
Сечение присоед жесткого кабеля mm²
Height mm
Depth mm
Weight kg
An area provided for marking allows you to make indication of compliance to the scheme, that simplifies the installation.
An area provided for marking allows you to make indication of compliance to the scheme, that simplifies the installation.
An indicator on the front panel informs about the current state of opening and closing contacts.
An indicator on the front panel informs about the current state of opening and closing contacts.
Sealing of the transparent cover protecting the setpoint adjustment disk, eliminates an unauthorized access to the setpoints of operating current values.
Sealing of the transparent cover protecting the setpoint adjustment disk, eliminates an unauthorized access to the setpoints of operating current values.
TEST button allows you to test the functionality of the device before connecting it to the power circuit.
TEST button allows you to test the functionality of the device before connecting it to the power circuit.
The possibility of a forced stop of the contactor.
The possibility of a forced stop of the contactor.
The process of restart may be performed in two modes: manual and automatic.
The process of restart may be performed in two modes: manual and automatic.