IEK
RSS Русский English Казахский Español Feedback Sitemap
Products catalog
Pricelist

02.03.03.01 Disconnectors RE-19

  • Description
  • Assortment
  • Design
    features
  • Package bundle
The disconnectors of RE-19 series are designed for conducting the rated current and not frequent non-automatic switching of circuits without load of rated voltage up to 1000V AC and frequency 50/60Hz. RE-19 IEK can be used in switchgears with rated currents from 250 to 1600A.
Sorting: article name
Total: 13 Go to page: 1 2
Disconnector PE19-35-31120 250A IEK
PE-31120-0250
Conditioned rated short-circuit current Iq: 14 kA
Number of poles: 3
Rated insulation voltage Ui: 660 V
Rated operating voltage Ue: 660 V
Disconnector PE19-35-31140 250A IEK
PE-31140-0250
Conditioned rated short-circuit current Iq: 14 kA
Number of poles: 3
Rated insulation voltage Ui: 660 V
Rated operating voltage Ue: 660 V
Disconnector PE19-37-31120 400A IEK
PE-31120-0400
Conditioned rated short-circuit current Iq: 26 kA
Number of poles: 3
Rated insulation voltage Ui: 660 V
Rated operating voltage Ue: 660 V
Disconnector PE19-37-31140 400A IEK
PE-31140-0400
Conditioned rated short-circuit current Iq: 26 kA
Number of poles: 3
Rated insulation voltage Ui: 660 V
Rated operating voltage Ue: 660 V
Disconnector PE19-39-31120 630A IEK
PE-31120-0630
Max. rated operation voltage Ue AC: 1000 V
Conditioned rated short-circuit current Iq: 32 kA
Number of poles: 3
Rated insulation voltage Ui: 1000 V
Disconnector PE19-39-31140 630A IEK
PE-31140-0630
Max. rated operation voltage Ue AC: 1000 V
Conditioned rated short-circuit current Iq: 32 kA
Number of poles: 3
Rated insulation voltage Ui: 1000 V
Disconnector PE19-39-31160 630A IEK
PE-31160-0630
Max. rated operation voltage Ue AC: 1000 V
Conditioned rated short-circuit current Iq: 32 kA
Number of poles: 3
Rated insulation voltage Ui: 1000 V
Disconnector PE19-41-31120 1000A IEK
PE-31120-1000
Max. rated operation voltage Ue AC: 1000 V
Conditioned rated short-circuit current Iq: 100 kA
Number of poles: 3
Rated insulation voltage Ui: 1000 V
Disconnector PE19-41-31140 1000A IEK
PE-31140-1000
Max. rated operation voltage Ue AC: 1000 V
Conditioned rated short-circuit current Iq: 100 kA
Number of poles: 3
Rated insulation voltage Ui: 1000 V
Disconnector PE19-41-31160 1000A IEK
PE-31160-1000
Max. rated operation voltage Ue AC: 1000 V
Conditioned rated short-circuit current Iq: 100 kA
Number of poles: 3
Rated insulation voltage Ui: 1000 V
Total: 13
1 2
Search by parameters
Conditioned rated short-circuit current Iq kA
Rated insulation voltage Ui V
A complete set of metalware for the installation and connection of conductors.
A complete set of metalware for the installation and connection of conductors.
Blade-type contact system provides a visible breakage of the circuit.
Blade-type contact system provides a visible breakage of the circuit.
Output terminals made of high quality electrical copper with a protective coating, allow to attach conductive copper and aluminum wires terminated cable lugs, as well as copper and aluminum busbars.
Output terminals made of high quality electrical copper with a protective coating, allow to attach conductive copper and aluminum wires terminated cable lugs, as well as copper and aluminum busbars.
The base is made of durable materials not supporting combustion.
The base is made of durable materials not supporting combustion.
Wide range of control knobs.
Wide range of control knobs.
Contact us Contact us:
+7 (495) 542 22 22
 
Copyright © 1999-2021 IEK. ALL RIGHTS RESERVED.