MCCB VA88-35R 3P 125A 35kA IEK
Article: SVAR30-3-0125
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 125 A
MCCB VA88-35R 3P 160A 35kA IEK
Article: SVAR30-3-0160
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 160 A
MCCB VA88-35R 3P 200A 35kA IEK
Article: SVAR30-3-0200
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 200 A
MCCB VA88-35R 3P 250A 35kA IEK
Article: SVAR30-3-0250
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 250 A
Total: 4
1
Search by parameters
Nominal rated current A
By means of special RCS bracket the VA88-32, VA88-33 breakers can be mounted on a DIN-rail.
By means of special RCS bracket the VA88-32, VA88-33 breakers can be mounted on a DIN-rail.
Current limit, i.e. the actual current during a short-circuit, which is much lower than the estimated one. This is realized due to the contacts separation speed, dynamic action of the magnetic field, and the arc chute design ensures the arc blowout in the shortest possible time.
Current limit, i.e. the actual current during a short-circuit, which is much lower than the estimated one. This is realized due to the contacts separation speed, dynamic action of the magnetic field, and the arc chute design ensures the arc blowout in the shortest possible time.
Double insulation - complete separation of the power and auxiliary circuits. The casing of each of the additional devices is placed in a separate niche, that completely eliminates the risk of contact with live parts and increases the safety of maintenance and inspection.
Double insulation - complete separation of the power and auxiliary circuits. The casing of each of the additional devices is placed in a separate niche, that completely eliminates the risk of contact with live parts and increases the safety of maintenance and inspection.
Full range of thermal releases makes it possible to provide selectivity in multi-stage protection system.
Full range of thermal releases makes it possible to provide selectivity in multi-stage protection system.
Large values of rated ultimate breaking capacity - up to 50 kA.
Large values of rated ultimate breaking capacity - up to 50 kA.
Plastic parts of switch casing are made of glass fiber reinforced polyamide providing resistance to deformation occurring during short circuit.
Plastic parts of switch casing are made of glass fiber reinforced polyamide providing resistance to deformation occurring during short circuit.
VA88 circuit breaker design allows to install additional devices.
VA88 circuit breaker design allows to install additional devices.
VA88 switches can be mounted in any position without change in their nominal characteristics. VA88 switches can be powered through the upper or lower terminals without disturbing the performance.
VA88 switches can be mounted in any position without change in their nominal characteristics. VA88 switches can be powered through the upper or lower terminals without disturbing the performance.