IEK
RSS Русский English Казахский Español Feedback Sitemap
Products catalog
Pricelist

02.01.02.01.05 Moulded case circuit breakers VA88 произведено РФ

  • Assortment
  • Design
    features
  • Package bundle
Sorting: article name
Total: 13 Go to page: 1 2
Авт. выкл. ВА88-32 3Р 12,5А 25кА IEK
Article: SVA10-3-0012-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 12,5 A
Авт. выкл. ВА88-32 3Р 25А 25кА IEK
Article: SVA10-3-0025-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 25 A
Авт. выкл. ВА88-32 3Р 40А 25кА IEK
Article: SVA10-3-0040-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 40 A
Авт. выкл. ВА88-32 3Р 80А 25кА IEK
Article: SVA10-3-0080-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 25 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 80 A
Авт. выкл. ВА88-33 3Р 160А 35кА IEK
Article: SVA20-3-0160-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 160 A
Авт. выкл. ВА88-33 3Р 40А 35кА IEK
Article: SVA20-3-0040-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 40 A
Авт. выкл. ВА88-33 3Р 63А 35кА IEK
Article: SVA20-3-0063-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 63 A
Авт. выкл. ВА88-35 3Р 125А 35кА IEK
Article: SVA30-3-0125-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 125 A
Авт. выкл. ВА88-35 3Р 80А 35кА IEK
Article: SVA30-3-0080-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 80 A
Авт. выкл. ВА88-37 3Р 315А 35кА IEK
Article: SVA40-3-0315-R
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 35 kA
Number of poles: 3
Rated surge voltage invariability: 8 kV
Nominal rated current: 315 A
Total: 13
1 2
Search by parameters
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz kA
Nominal rated current A
Номин раб наибольшая откл способность Ics kA
By means of special RCS bracket the VA88-32, VA88-33 breakers can be mounted on a DIN-rail.
By means of special RCS bracket the VA88-32, VA88-33 breakers can be mounted on a DIN-rail.
Current limit, i.e. the actual current during a short-circuit, which is much lower than the estimated one. This is realized due to the contacts separation speed, dynamic action of the magnetic field, and the arc chute design ensures the arc blowout in the shortest possible time.
Current limit, i.e. the actual current during a short-circuit, which is much lower than the estimated one. This is realized due to the contacts separation speed, dynamic action of the magnetic field, and the arc chute design ensures the arc blowout in the shortest possible time.
Double insulation - complete separation of the power and auxiliary circuits. The casing of each of the additional devices is placed in a separate niche, that completely eliminates the risk of contact with live parts and increases the safety of maintenance and inspection.
Double insulation - complete separation of the power and auxiliary circuits. The casing of each of the additional devices is placed in a separate niche, that completely eliminates the risk of contact with live parts and increases the safety of maintenance and inspection.
Full range of thermal releases makes it possible to provide selectivity in multi-stage protection system.
Full range of thermal releases makes it possible to provide selectivity in multi-stage protection system.
Large values of rated ultimate breaking capacity - up to 50 kA.
Large values of rated ultimate breaking capacity - up to 50 kA.
Plastic parts of switch casing are made of glass fiber reinforced polyamide providing resistance to deformation occurring during short circuit.
Plastic parts of switch casing are made of glass fiber reinforced polyamide providing resistance to deformation occurring during short circuit.
VA88 circuit breaker design allows to install additional devices.
VA88 circuit breaker design allows to install additional devices.
VA88 switches can be mounted in any position without change in their nominal characteristics. VA88 switches can be powered through the upper or lower terminals without disturbing the performance.
VA88 switches can be mounted in any position without change in their nominal characteristics. VA88 switches can be powered through the upper or lower terminals without disturbing the performance.
Contact us Contact us:
+7 (495) 542 22 22
 
Copyright © 1999-2021 IEK. ALL RIGHTS RESERVED.