02.04.03.01 Air circuit breakers VA07 and additional devices

  • Description
  • Assortment
  • Design
    features
  • Package bundle
VA07 circuit breakers are installed into transformer substations, switch and control gears and main distribution boards as lead-in, sectional and distribution units for connecting and protecting drives, generators, transformers, buses and cables at industrial and residential construction sites, electric supply of high technology manufactures, banks and utilities. Intended for exploitation in electric units with rated operating voltage limited to 690V per rated current from 800 to 4000A. These ACB correspond to the requirements of IEC 60947-2.
Sorting: article name
Total: 13 Go to page: 1 2
Air circuit breaker VA07-208 fixed with undervoltage trip 3P 800A 65kA IEK
Article: SAB231-0800-U11H-P11
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 65 kA
Number of auxiliary contacts as change-over contact: 4
Number of poles: 3
Nominal rated current: 800 A
Выкл. авт. ВА07-212 выдвиж с мин. расц. 3P 1250А 65кА ИЭК
Article: SAB230-1250-U11H-P11
Rated permanent current Iu: 1250 A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 65 kA
Number of poles: 3
Air circuit breaker VA07-220 draw-out with undervoltage trip 3P 2000A 65kA IEK
Article: SAB230-2000-U11H-P11
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 65 kA
Number of auxiliary contacts as change-over contact: 4
Number of poles: 3
Nominal rated current: 2000 A
Air circuit breaker VA07-332 draw-out with undervoltage trip 3P 3200A 85kA IEK
Article: SAB330-3200-U11H-P11
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 85 kA
Number of auxiliary contacts as change-over contact: 4
Number of poles: 3
Nominal rated current: 3200 A
Air circuit breaker VA07-332 fixed with shunt trip 3P 3200A 85kA IEK
Article: SAB331-3200-S11H-P11
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 85 kA
Number of auxiliary contacts as change-over contact: 4
Number of poles: 3
Nominal rated current: 3200 A
Air circuit breaker VA07-M with integrated trip draw-out 3P 1250A Icu=80kA IEK
Article: SAB-2000-KRV-3P-1250A-80
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 80 kA
Setting range over-current release: (0,4÷1) In A
Adjustment range short-term delayed short-circuit release: (1,3÷15) Ir или OFF A
Adjustment range undelayed short-circuit release: 1,3In÷50000 A
Air circuit breaker VA07-M with integrated trip draw-out 3P 2000A Icu=80kA IEK
Article: SAB-2000-KRV-3P-2000A-80
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 80 kA
Setting range over-current release: (0,4÷1) In A
Adjustment range short-term delayed short-circuit release: (1,3÷15) Ir или OFF A
Adjustment range undelayed short-circuit release: 1,3In÷65000 A
Air circuit breaker VA07-M with integrated trip draw-out 3P 2500A Icu=80kA IEK
Article: SAB-3200-KRV-3P-2500A-80
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 80 kA
Setting range over-current release: (0,4÷1) In A
Adjustment range short-term delayed short-circuit release: (1,3÷15) Ir ÷ 40000 A
Adjustment range undelayed short-circuit release: 1,3In÷65000 A
Air circuit breaker VA07-M with integrated trip fixed 3P 1250A Icu=80kA IEK
Article: SAB-2000-KRS-3P-1250A-80
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 80 kA
Setting range over-current release: (0,4÷1) In A
Adjustment range short-term delayed short-circuit release: (1,3÷15) Ir или OFF A
Adjustment range undelayed short-circuit release: 1,3In÷50000 A
Air circuit breaker VA07-M with integrated trip fixed 3P 3200A Icu=80kA IEK
Article: SAB-3200-KRS-3P-3200A-80
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz: 80 kA
Setting range over-current release: (0,4÷1) In A
Adjustment range short-term delayed short-circuit release: (1,3÷15) Ir ÷ 40000 A
Adjustment range undelayed short-circuit release: 1,3In÷65000 A
Total: 13
1 2
Search by parameters
Select a product type to go to the search by parameters
All types of the units with a rated current of 3200 A have the same depth of 345 mm and a height of 460 mm. The size of the hole in the board for the front panel is the same for all switches of VA07 series, that facilitates the installation of the equipment in the junction box.
All types of the units with a rated current of 3200 A have the same depth of 345 mm and a height of 460 mm. The size of the hole in the board for the front panel is the same for all switches of VA07 series, that facilitates the installation of the equipment in the junction box.
Basic complete sets of the supply provide that the main contacts for devices up to 3200 A are installed in horizontal position, and for the current of 4000 A - in vertical position. Front-face and the combined connection is possible as well.
Basic complete sets of the supply provide that the main contacts for devices up to 3200 A are installed in horizontal position, and for the current of 4000 A - in vertical position. Front-face and the combined connection is possible as well.
Double Break system ensures quick break of short circuit current arc by splitting the arch into halves through opening at two points of each pole. This reduces contact wear and reduces their erosion.
Double Break system ensures quick break of short circuit current arc by splitting the arch into halves through opening at two points of each pole. This reduces contact wear and reduces their erosion.
Main contacts can easily be replaced, thus extending the life of the circuit breaker. Replacement of each contact takes no more than 15 minutes.
Main contacts can easily be replaced, thus extending the life of the circuit breaker. Replacement of each contact takes no more than 15 minutes.
The use of electronic release providing the following functions:
- protection against continuous overload;
- short-circuit protection;
- adjustable function of instantaneous trip.
The use of electronic release providing the following functions: - protection against continuous overload; - short-circuit protection; - adjustable function of instantaneous trip.
The use of two transformers on each pole. The first transformer is linear which controls the current signal. It provides a high grade of accuracy over the entire range of short circuit currents. The second transformer is designed to power the electronic trip unit.
The use of two transformers on each pole. The first transformer is linear which controls the current signal. It provides a high grade of accuracy over the entire range of short circuit currents. The second transformer is designed to power the electronic trip unit.