IEK
RSS Русский English Казахский Español Feedback Sitemap
Products catalog
Pricelist

01.02.02.03.02 Residual current breakers operated AVDT34

  • Description
  • Assortment
  • Design
    features
  • Package bundle
KARAT Residual current devices are presented by VD Residual current circuit breakers (RCCB), AD and AVDT residual current breakers operated (RCBO). VD Residual current circuit breakers (RCCB) are designed to protect a person from electric shock in case of accidental unintentional contact with live parts of electrical installations and prevent fires due to leakage currents to earth. It does not have its own power consumption and has a high mechanical wear resistance. AD and AVDT residual current breakers operated (RCBO) provide: – in versions with actuation settings of 10, 30 and 100 mA - protection of people from electric shock in case of direct unintentional contact with live parts of electrical equipment; – in a version with a 300 mA actuation setting - protection against fire due to ignition of the insulation of live parts; - overload and short circuit protection; - protection against unacceptable increase in mains voltage (AD12M). The products provide indication of operation from the leakage current, and for AD12M there is also LED indication of the on state. AD12M remains operational when the voltage of the electrical network drops to 50 V. As switching devices in the products, automatic circuit breakers VA47-29 of a new series are used. RCBO residual current circuit breakers are designed to protect a person from electric shock when the insulation of electrical installations is damaged, to prevent fires due to leakage currents to earth and to protect against overload and short circuits. Recommended for protecting group lines supplying outdoor sockets, sockets and lighting in basements and garages.
Sorting: article name
Total: 22 Go to page: 1 2 3
RCBO AVDT 34 C10 10mA 6kA IEK
Article: MAD22-6-010-C-10
Number of poles: 4
Number of protected poles: 3
Primary current: 10 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C10 30mA 6kA IEK
Article: MAD22-6-010-C-30
Number of poles: 4
Number of protected poles: 3
Primary current: 10 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C16 100mA 6kA IEK
Article: MAD22-6-016-C-100
Number of poles: 4
Number of protected poles: 3
Primary current: 16 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C16 10mA 6kA IEK
Article: MAD22-6-016-C-10
Number of poles: 4
Number of protected poles: 3
Primary current: 16 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C16 300mA 6kA IEK
Article: MAD22-6-016-C-300
Number of poles: 4
Number of protected poles: 3
Primary current: 16 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C16 30mA 6kA IEK
Article: MAD22-6-016-C-30
Number of poles: 4
Number of protected poles: 3
Primary current: 16 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C20 30mA 6kA IEK
Article: MAD22-6-020-C-30
Number of poles: 4
Number of protected poles: 3
Primary current: 20 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C25 100mA 6kA IEK
Article: MAD22-6-025-C-100
Number of poles: 4
Number of protected poles: 3
Primary current: 25 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C25 300mA 6kA IEK
Article: MAD22-6-025-C-300
Number of poles: 4
Number of protected poles: 3
Primary current: 25 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C25 30mA 6kA IEK
Article: MAD22-6-025-C-30
Number of poles: 4
Number of protected poles: 3
Primary current: 25 A
Nominal rated voltage: 400 V
Total: 22
1 2 3
Search by parameters
Primary current A
Номин откл диф ток mA
Anti-interference scheme excluding the faulty actuation: № RU Patent No. 124453.
Anti-interference scheme excluding the faulty actuation: № RU Patent No. 124453.
Arc chute made of 13 steel plates in order to effectively quench the arc.
Arc chute made of 13 steel plates in order to effectively quench the arc.
Arc removal plate of movable contact is made as a smooth curve, that greatly facilitates the pulling of the arc into the arc chute.
Arc removal plate of movable contact is made as a smooth curve, that greatly facilitates the pulling of the arc into the arc chute.
Expansion of RCBO34 (AVDT34) line for 40, 50, 63A currents with the setting of 30, 100, 300 mA.
Expansion of RCBO34 (AVDT34) line for 40, 50, 63A currents with the setting of 30, 100, 300 mA.
Latch on a DIN-rail with double fixed position for ease of installation work.
Latch on a DIN-rail with double fixed position for ease of installation work.
Notches on the contact clamps reduce heat loss and increase the mechanical stability of the connection.
Notches on the contact clamps reduce heat loss and increase the mechanical stability of the connection.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
The compact design of the automatic circuit breaker controlled by residual current, with integrated overcurrent protection, holds 4 standard modules on the panel.
The compact design of the automatic circuit breaker controlled by residual current, with integrated overcurrent protection, holds 4 standard modules on the panel.
The indicator of status of the main circuit provides accurate information about the status of contacts regardless of handle position. The rated conditional short circuit current is 6000 A. The extended range of operating temperatures is from -25 °C to + 40 ° C.
The indicator of status of the main circuit provides accurate information about the status of contacts regardless of handle position. The rated conditional short circuit current is 6000 A. The extended range of operating temperatures is from -25 °C to + 40 ° C.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The RCBO34 (AVDT34) design for the currents above 40A provides quick assembly / disassembly without the use of tools and a stable fit on DIN-rail.
The RCBO34 (AVDT34) design for the currents above 40A provides quick assembly / disassembly without the use of tools and a stable fit on DIN-rail.
Trip-free mechanism of the new design, which ensures a quick break of the main contacts.
Trip-free mechanism of the new design, which ensures a quick break of the main contacts.
Contact us Contact us:
+7 (495) 542 22 22
 