KARAT Residual current devices are presented by VD Residual current circuit breakers (RCCB), AD and AVDT residual current breakers operated (RCBO). VD Residual current circuit breakers (RCCB) are designed to protect a person from electric shock in case of accidental unintentional contact with live parts of electrical installations and prevent fires due to leakage currents to earth. It does not have its own power consumption and has a high mechanical wear resistance. AD and AVDT residual current breakers operated (RCBO) provide: – in versions with actuation settings of 10, 30 and 100 mA - protection of people from electric shock in case of direct unintentional contact with live parts of electrical equipment; – in a version with a 300 mA actuation setting - protection against fire due to ignition of the insulation of live parts; - overload and short circuit protection; - protection against unacceptable increase in mains voltage (AD12M). The products provide indication of operation from the leakage current, and for AD12M there is also LED indication of the on state. AD12M remains operational when the voltage of the electrical network drops to 50 V. As switching devices in the products, automatic circuit breakers VA47-29 of a new series are used. RCBO residual current circuit breakers are designed to protect a person from electric shock when the insulation of electrical installations is damaged, to prevent fires due to leakage currents to earth and to protect against overload and short circuits. Recommended for protecting group lines supplying outdoor sockets, sockets and lighting in basements and garages.
Sorting: article name
Total: 12 Go to page: 1 2
RCBO AVDT 32 B16 10mA IEK
Article: MAD22-5-016-B-10
Number of poles: 2
Number of protected poles: 1
Primary current: 16 A
Nominal rated voltage: 230 V
RCBO AVDT 32 B25 10mA IEK
Article: MAD22-5-025-B-10
Number of poles: 2
Number of protected poles: 1
Primary current: 25 A
Nominal rated voltage: 230 V
RCBO AVDT 32 C10 IEK
Article: MAD22-5-010-C-30
Number of poles: 2
Number of protected poles: 1
Primary current: 10 A
Nominal rated voltage: 230 V
RCBO AVDT 32 C16 IEK
Article: MAD22-5-016-C-30
Number of poles: 2
Number of protected poles: 1
Primary current: 16 A
Nominal rated voltage: 230 V
RCBO AVDT 32 C20 IEK
Article: MAD22-5-020-C-30
Number of poles: 2
Number of protected poles: 1
Primary current: 20 A
Nominal rated voltage: 230 V
RCBO AVDT 32 C25 IEK
Article: MAD22-5-025-C-30
Number of poles: 2
Number of protected poles: 1
Primary current: 25 A
Nominal rated voltage: 230 V
RCBO AVDT 32 C32 IEK
Article: MAD22-5-032-C-30
Number of poles: 2
Number of protected poles: 1
Primary current: 32 A
Nominal rated voltage: 230 V
RCBO AVDT 32 C40 100mA IEK
Article: MAD22-5-040-C-100
Number of poles: 2
Number of protected poles: 1
Primary current: 40 A
Nominal rated voltage: 230 V
RCBO AVDT 32 C40 30mA IEK
Article: MAD22-5-040-C-30
Number of poles: 2
Number of protected poles: 1
Primary current: 40 A
Nominal rated voltage: 230 V
RCBO AVDT 32 C50 100mA IEK
Article: MAD22-5-050-C-100
Number of poles: 2
Number of protected poles: 1
Primary current: 50 A
Nominal rated voltage: 230 V
Total: 12
1 2
Search by parameters
Primary current A
Номин откл диф ток mA
Built-in depth mm
A wide range of operating temperatures from -25 °C to + 50 °C allows the use of the switch in different climatic zones.
A wide range of operating temperatures from -25 °C to + 50 °C allows the use of the switch in different climatic zones.
Additional protection against burning of machine casing due to the arc and the heat removal due to fire resistant plate.
Additional protection against burning of machine casing due to the arc and the heat removal due to fire resistant plate.
Anti-interference scheme excluding the faulty actuation: № RU Patent No. 124453.
Anti-interference scheme excluding the faulty actuation: № RU Patent No. 124453.
Arc chute made of 13 steel plates in order to effectively quench the arc.
Arc chute made of 13 steel plates in order to effectively quench the arc.
Combined circuit with electronic module of differential protection, class D variator and integrated switch of VA47-60 series provides 4 types of protection: against differential current (leakage current), short-circuit, overload and protection of internal parts of the device against overvoltage.
Combined circuit with electronic module of differential protection, class D variator and integrated switch of VA47-60 series provides 4 types of protection: against differential current (leakage current), short-circuit, overload and protection of internal parts of the device against overvoltage.
Notches on the contact clamps reduce heat loss and increase the mechanical stability of the connection.
Notches on the contact clamps reduce heat loss and increase the mechanical stability of the connection.
Quick mounting and more reliable mounting on a DIN-rail by means of latches in dual fixed position.
Quick mounting and more reliable mounting on a DIN-rail by means of latches in dual fixed position.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The status indicator of the main circuit provides accurate information on the status of contacts regardless of handle position.
The status indicator of the main circuit provides accurate information on the status of contacts regardless of handle position.
A wide range of operating temperatures from -25 °C to + 50 °C allows the use of the switch in different climatic zones.
A wide range of operating temperatures from -25 °C to + 50 °C allows the use of the switch in different climatic zones.
Anti-interference scheme excluding the faulty actuation: № RU Patent No. 124453.
Anti-interference scheme excluding the faulty actuation: № RU Patent No. 124453.
Combined circuit with electronic module of differential protection, class D variator and integrated switch of VA47-60 series provides 4 types of protection: against differential current (leakage current), short-circuit, overload and protection of internal parts of the device against overvoltage.
Combined circuit with electronic module of differential protection, class D variator and integrated switch of VA47-60 series provides 4 types of protection: against differential current (leakage current), short-circuit, overload and protection of internal parts of the device against overvoltage.
Energy-efficient and compact design; the differential block is shifted to the bottom of the unit.
Energy-efficient and compact design; the differential block is shifted to the bottom of the unit.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
The increased strength in the area of conductors connection is achieved due to two additional rivets.
The increased strength in the area of conductors connection is achieved due to two additional rivets.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The RCBO32 (AVDT32) design for the currents above 40A provides quick assembly / disassembly without the use of tools and a stable fit on DIN-rail.
The RCBO32 (AVDT32) design for the currents above 40A provides quick assembly / disassembly without the use of tools and a stable fit on DIN-rail.
Contact us Contact us:
+7 (495) 542 22 22
 
Copyright © 1999-2021 IEK. ALL RIGHTS RESERVED.