01.02.02.02.01 Residual current breakers operated AD12_14 type AC

  • Description
  • Assortment
  • Design
    features
  • Package bundle
KARAT Residual current devices are presented by VD Residual current circuit breakers (RCCB), AD and AVDT residual current breakers operated (RCBO). VD Residual current circuit breakers (RCCB) are designed to protect a person from electric shock in case of accidental unintentional contact with live parts of electrical installations and prevent fires due to leakage currents to earth. It does not have its own power consumption and has a high mechanical wear resistance. AD and AVDT residual current breakers operated (RCBO) provide: – in versions with actuation settings of 10, 30 and 100 mA - protection of people from electric shock in case of direct unintentional contact with live parts of electrical equipment; – in a version with a 300 mA actuation setting - protection against fire due to ignition of the insulation of live parts; - overload and short circuit protection; - protection against unacceptable increase in mains voltage (AD12M). The products provide indication of operation from the leakage current, and for AD12M there is also LED indication of the on state. AD12M remains operational when the voltage of the electrical network drops to 50 V. As switching devices in the products, automatic circuit breakers VA47-29 of a new series are used. RCBO residual current circuit breakers are designed to protect a person from electric shock when the insulation of electrical installations is damaged, to prevent fires due to leakage currents to earth and to protect against overload and short circuits. Recommended for protecting group lines supplying outdoor sockets, sockets and lighting in basements and garages.
Sorting: article name
Total: 49 Go to page: 1 2 3 4 5
RCBO AD12 2P 10A 100mA IEK
Article: MAD10-2-010-C-100
Number of poles: 2
Number of protected poles: 2
Primary current: 10 A
Nominal rated voltage: 230 V
RCBO AD12 2P 10A 10mA IEK
Article: MAD10-2-010-C-010
Number of poles: 2
Number of protected poles: 2
Primary current: 10 A
Nominal rated voltage: 230 V
RCBO AD12 2P 10A 30mA IEK
Article: MAD10-2-010-C-030
Number of poles: 2
Number of protected poles: 2
Primary current: 10 A
Nominal rated voltage: 230 V
RCBO AD12 2P 16A 100mA IEK
Article: MAD10-2-016-C-100
Number of poles: 2
Number of protected poles: 2
Primary current: 16 A
Nominal rated voltage: 230 V
RCBO AD12 2P 16A 10mA IEK
Article: MAD10-2-016-C-010
Number of poles: 2
Number of protected poles: 2
Primary current: 16 A
Nominal rated voltage: 230 V
RCBO AD12 2P 16A 30mA IEK
Article: MAD10-2-016-C-030
Number of poles: 2
Number of protected poles: 2
Primary current: 16 A
Nominal rated voltage: 230 V
RCBO AD12 2P 20A 30mA IEK
Article: MAD10-2-020-C-030
Number of poles: 2
Number of protected poles: 2
Primary current: 20 A
Nominal rated voltage: 230 V
RCBO AD12 2P 25A 100mA IEK
Article: MAD10-2-025-C-100
Number of poles: 2
Number of protected poles: 2
Primary current: 25 A
Nominal rated voltage: 230 V
RCBO AD12 2P 25A 10mA IEK
Article: MAD10-2-025-C-010
Number of poles: 2
Number of protected poles: 2
Primary current: 25 A
Nominal rated voltage: 230 V
RCBO AD12 2P 25A 300mA IEK
Article: MAD10-2-025-C-300
Number of poles: 2
Number of protected poles: 2
Primary current: 25 A
Nominal rated voltage: 230 V
Total: 49
1 2 3 4 5
Search by parameters
Number of poles
Number of protected poles
Primary current A
Nominal rated voltage V
Номин откл диф ток mA
Compact, energy-efficient design: due to the use of a differential block of smaller size it saves space in the switchboards.
Compact, energy-efficient design: due to the use of a differential block of smaller size it saves space in the switchboards.
Convenient assembly / disassembly without the use of tools.
Convenient assembly / disassembly without the use of tools.
Improved arc blowout system: patent No. RU 139886.
Improved arc blowout system: patent No. RU 139886.
Increased strength in the area of conductors connection due to two additional rivets and monolithic faceplate.
Increased strength in the area of conductors connection due to two additional rivets and monolithic faceplate.
Indicator of actuation due to residual current:
Indicator of actuation due to residual current: "Return" button. For AD12/14 - “AS” characteristic, for AD12M - “A” characteristic.
LED indication of the voltage on the
LED indication of the voltage on the "Load" terminals and the built-in protection against long-term (265V; 0.5s) mains overvoltage (AD12M).
New design of AD12 / 12M / 14 allows you to attach additional devices KS47, KSV47 without the use of screws.
New design of AD12 / 12M / 14 allows you to attach additional devices KS47, KSV47 without the use of screws.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The presence of the indicator of contacts position.
The presence of the indicator of contacts position.