01.02.03.02 AVDT34 6kA

  • Description
  • Assortment
  • Design
    features
  • Package bundle
Residual Current Circuit Breakers with Overload protection (RCBO) AVDT32 are designed for protection of persons against electric shock in case of damaged insulation in electric installations, preventing fires caused by earth leakage currents and protection against overloads and short-circuits.
Sorting: article name
Total: 22 Go to page: 1 2 3
RCBO AVDT 34 C10 10mA 6kA IEK
MAD22-6-010-C-10
Number of poles: 4
Number of protected poles: 3
Primary current: 10 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C10 30mA 6kA IEK
MAD22-6-010-C-30
Number of poles: 4
Number of protected poles: 3
Primary current: 10 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C16 100mA 6kA IEK
MAD22-6-016-C-100
Number of poles: 4
Number of protected poles: 3
Primary current: 16 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C16 10mA 6kA IEK
MAD22-6-016-C-10
Number of poles: 4
Number of protected poles: 3
Primary current: 16 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C16 300mA 6kA IEK
MAD22-6-016-C-300
Number of poles: 4
Number of protected poles: 3
Primary current: 16 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C16 30mA 6kA IEK
MAD22-6-016-C-30
Number of poles: 4
Number of protected poles: 3
Primary current: 16 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C20 30mA 6kA IEK
MAD22-6-020-C-30
Number of poles: 4
Number of protected poles: 3
Primary current: 20 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C25 100mA 6kA IEK
MAD22-6-025-C-100
Number of poles: 4
Number of protected poles: 3
Primary current: 25 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C25 300mA 6kA IEK
MAD22-6-025-C-300
Number of poles: 4
Number of protected poles: 3
Primary current: 25 A
Nominal rated voltage: 400 V
RCBO AVDT 34 C25 30mA 6kA IEK
MAD22-6-025-C-30
Number of poles: 4
Number of protected poles: 3
Primary current: 25 A
Nominal rated voltage: 400 V
Total: 22
1 2 3
Search by parameters
Primary current A
Номин откл диф ток mA
Anti-interference scheme excluding the faulty actuation: № RU Patent No. 124453.
Anti-interference scheme excluding the faulty actuation: № RU Patent No. 124453.
Arc chute made of 13 steel plates in order to effectively quench the arc.
Arc chute made of 13 steel plates in order to effectively quench the arc.
Arc removal plate of movable contact is made as a smooth curve, that greatly facilitates the pulling of the arc into the arc chute.
Arc removal plate of movable contact is made as a smooth curve, that greatly facilitates the pulling of the arc into the arc chute.
Expansion of RCBO34 (AVDT34) line for 40, 50, 63A currents with the setting of 30, 100, 300 mA.
Expansion of RCBO34 (AVDT34) line for 40, 50, 63A currents with the setting of 30, 100, 300 mA.
Latch on a DIN-rail with double fixed position for ease of installation work.
Latch on a DIN-rail with double fixed position for ease of installation work.
Notches on the contact clamps reduce heat loss and increase the mechanical stability of the connection.
Notches on the contact clamps reduce heat loss and increase the mechanical stability of the connection.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
The compact design of the automatic circuit breaker controlled by residual current, with integrated overcurrent protection, holds 4 standard modules on the panel.
The compact design of the automatic circuit breaker controlled by residual current, with integrated overcurrent protection, holds 4 standard modules on the panel.
The indicator of status of the main circuit provides accurate information about the status of contacts regardless of handle position. The rated conditional short circuit current is 6000 A. The extended range of operating temperatures is from -25 °C to + 40 ° C.
The indicator of status of the main circuit provides accurate information about the status of contacts regardless of handle position. The rated conditional short circuit current is 6000 A. The extended range of operating temperatures is from -25 °C to + 40 ° C.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The possibility of simultaneous connection of FORK bus and flexible conductor for the distribution of circuit power supply through the upper terminal clamps, as well as the possibility of connection via PIN bus.
The RCBO34 (AVDT34) design for the currents above 40A provides quick assembly / disassembly without the use of tools and a stable fit on DIN-rail.
The RCBO34 (AVDT34) design for the currents above 40A provides quick assembly / disassembly without the use of tools and a stable fit on DIN-rail.
Trip-free mechanism of the new design, which ensures a quick break of the main contacts.
Trip-free mechanism of the new design, which ensures a quick break of the main contacts.