IEK
RSS Русский English Казахский Español Feedback Sitemap
Products catalog
Pricelist

01.02.03.03 AVDT32M

  • Description
  • Assortment
  • Design
    features
  • Package bundle
Residual Current Circuit Breakers with Overload protection (RCBO) AVDT32 are designed for protection of persons against electric shock in case of damaged insulation in electric installations, preventing fires caused by earth leakage currents and protection against overloads and short-circuits.
Sorting: article name
Total: 15 Go to page: 1 2
RCBO AVDT32M V10 30mA IEK IEK
MAD32-5-010-B-30
Number of poles: 1+N
Number of protected poles: 1
Primary current: 10 A
Nominal rated voltage: 230 V
RCBO AVDT32M V16 30mA IEK IEK
MAD32-5-016-B-30
Number of poles: 1+N
Number of protected poles: 1
Primary current: 16 A
Nominal rated voltage: 230 V
RCBO AVDT32M V6 10mA IEK IEK
MAD32-5-006-B-10
Number of poles: 1+N
Number of protected poles: 1
Primary current: 6 A
Nominal rated voltage: 230 V
RCBO AVDT32M C10 10mA IEK IEK
MAD32-5-010-C-10
Number of poles: 1+N
Number of protected poles: 1
Primary current: 10 A
Nominal rated voltage: 230 V
RCBO AVDT32M C10 30mA IEK IEK
MAD32-5-010-C-30
Number of poles: 1+N
Number of protected poles: 1
Primary current: 10 A
Nominal rated voltage: 220 V
RCBO AVDT32M C16 10mA IEK IEK
MAD32-5-016-C-10
Number of poles: 1+N
Number of protected poles: 1
Primary current: 16 A
Nominal rated voltage: 230 V
RCBO AVDT32M C16 30mA IEK IEK
MAD32-5-016-C-30
Number of poles: 1+N
Number of protected poles: 1
Primary current: 16 A
Nominal rated voltage: 220 V
RCBO AVDT32M C20 30mA IEK IEK
MAD32-5-020-C-30
Number of poles: 1+N
Number of protected poles: 1
Primary current: 20 A
Nominal rated voltage: 220 V
RCBO AVDT32M C25 10mA IEK IEK
MAD32-5-025-C-10
Number of poles: 1+N
Number of protected poles: 1
Primary current: 25 A
Nominal rated voltage: 230 V
RCBO AVDT32M C25 30mA IEK IEK
MAD32-5-025-C-30
Number of poles: 1+N
Number of protected poles: 1
Primary current: 25 A
Nominal rated voltage: 220 V
Total: 15
1 2
Search by parameters
Primary current A
Nominal rated voltage V
Номин откл диф ток mA
"TEST" button to check the device operation and correct connection.
A wide range of operating temperatures from -25 °C to + 40 °C allows the use of the switch in different climatic zones.
A wide range of operating temperatures from -25 °C to + 40 °C allows the use of the switch in different climatic zones.
Latch with dual fixed position for easy installation.
Latch with dual fixed position for easy installation.
Notches on the contact clamps reduce heat loss and increase the mechanical stability of the connection.
Notches on the contact clamps reduce heat loss and increase the mechanical stability of the connection.
Single-module design (18mm) - space saving on the panel.
Single-module design (18mm) - space saving on the panel.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
Soldering of the silver-containing composite increases the wear resistance of the contact group and reduces the contact resistance.
Contact us Contact us:
+7 (495) 542 22 22
 
Copyright © 1999-2021 IEK. ALL RIGHTS RESERVED.