IEK
RSS Русский English Казахский Español Feedback Sitemap
Products catalog
Pricelist

01.03.04 Modular contactors KM

  • Description
  • Assortment
  • Design
    features
  • Package bundle
01.03.04 Modular contactors KM
KM type module contactors are intended for use in AC networks of 400V (50Hz) and serve for commutating low inductance loads with rated currents up to 63V. They are applied for automation and control of various technological processes including that of lighting, ventilation and conditioning systems.
Sorting: article name
Total: 33 Go to page: 1 2 3 4
Novelty Контакт дополнительный ДК11-КМ 1НО+1НЗ KARAT IEK
MKK00D-DK-11
Novelty Additional Contact DK-KM 2NO IEK
MKK00D-DK-20
Modular contactors KM KM20-11M AC IEK
MKK11-20-11
Rated operation current: 20 A
Number of normally open contacts: 1
Number of normally closed contacts: 1
Rated operating voltage: 230 V
Module contactor KM20-20 AC/DC IEK
MKK10-20-20
Rated operation current: 20 A
Number of normally open contacts: 2
Rated operating voltage: 230 V
Width in number of modular spacings: 18
Modular contactors KM KM20-20M AC IEK
MKK11-20-20
Rated operation current: 20 A
Number of normally open contacts: 2
Rated operating voltage: 230 V
Width in number of modular spacings: 18
Modular contactors KM KM20-22M AC IEK
MKK11-20-22
Rated operation current: 20 A
Number of normally open contacts: 2
Number of normally closed contacts: 2
Rated operating voltage: 400 V
Module contactor KM20-40 AC IEK
MKK20-20-40
Rated operation current: 20 A
Number of normally open contacts: 4
Rated operating voltage: 400 V
Width in number of modular spacings: 36
Modular contactors KM KM20-40M AC IEK
MKK11-20-40
Rated operation current: 20 A
Number of normally open contacts: 4
Rated operating voltage: 400 V
Width in number of modular spacings: 36
Modular contactors KM KM25-22M AC IEK
MKK11-25-22
Rated operation current: 25 A
Number of normally open contacts: 2
Number of normally closed contacts: 2
Rated operating voltage: 400 V
Module contactor KM25-40 AC/DC IEK
MKK20-25-40
Rated operation current: 25 A
Number of normally open contacts: 4
Rated operating voltage: 400 V
Width in number of modular spacings: 54
Total: 33
1 2 3 4
Search by parameters
Rated operation current A
Number of normally open contacts
Rated operating voltage V
Width in number of modular spacings мм
Auxiliary contact interchanges control coil windings, decreasing the holding current by 5 times compared with the start current.
Auxiliary contact interchanges control coil windings, decreasing the holding current by 5 times compared with the start current.
Bridging contact provides high electrical insulation properties.
Bridging contact provides high electrical insulation properties.
Compatibility of sizes allows you to install the contactor in a standard board with any devices of modular series.
Compatibility of sizes allows you to install the contactor in a standard board with any devices of modular series.
Connection terminals allow you to connect the conductors of a cross section from 1 to 25 mm2.
Connection terminals allow you to connect the conductors of a cross section from 1 to 25 mm2.
Contacts are made of silver-containing material, it increases their durability, prolongs the service life and reduces the contact resistance and loss.
Contacts are made of silver-containing material, it increases their durability, prolongs the service life and reduces the contact resistance and loss.
In the control coil circuit a rectifier bridge is mounted that allows to control the 220 VDC coil.
In the control coil circuit a rectifier bridge is mounted that allows to control the 220 VDC coil.
Increased reliability due to the use of stranded conductor for connection of the coil winding.
Increased reliability due to the use of stranded conductor for connection of the coil winding.
Visual indication of the status of main contacts and main technical parameters.
Visual indication of the status of main contacts and main technical parameters.
Contact us Contact us:
+7 (495) 542 22 22
 
Copyright © 1999-2021 IEK. ALL RIGHTS RESERVED.