IEK
RSS Русский English Казахский Español Feedback Sitemap
Products catalog
Pricelist

01.03.02.15 Modular contactors KM

  • Description
  • Assortment
  • Design
    features
  • Package bundle
KARAT Additional devices include: VN-32 Switch disconnectors, which are used to turn on, conduct and turn off the rated current under normal operating conditions, conduct current in emergency modes, for example, during a short circuit, as well as to perform disconnection functions. OPS1 Surge protection devices (SPD) designed to protect internal distribution circuits of residential and public buildings from lightning and switching surge voltages. KM Modular contactors of type, which are intended for use in alternating current networks with voltage up to 400V, frequency 50Hz and are used for switching low-inductive loads with rated current up to 63A. As well as other additional devices that allow you to expand the optionality of modular automation.
Sorting: article name
Total: 33 Go to page: 1 2 3 4
Novelty Контакт дополнительный ДК11-КМ 1НО+1НЗ KARAT IEK
Article: MKK00D-DK-11
Novelty Additional Contact DK-KM 2NO IEK
Article: MKK00D-DK-20
Modular contactors KM KM20-11M AC IEK
Article: MKK11-20-11
Rated operation current: 20 A
Number of normally open contacts: 1
Number of normally closed contacts: 1
Rated operating voltage: 230 V
Module contactor KM20-20 AC/DC IEK
Article: MKK10-20-20
Rated operation current: 20 A
Number of normally open contacts: 2
Rated operating voltage: 230 V
Width in number of modular spacings: 18
Modular contactors KM KM20-20M AC IEK
Article: MKK11-20-20
Rated operation current: 20 A
Number of normally open contacts: 2
Rated operating voltage: 230 V
Width in number of modular spacings: 18
Modular contactors KM KM20-22M AC IEK
Article: MKK11-20-22
Rated operation current: 20 A
Number of normally open contacts: 2
Number of normally closed contacts: 2
Rated operating voltage: 400 V
Module contactor KM20-40 AC IEK
Article: MKK20-20-40
Rated operation current: 20 A
Number of normally open contacts: 4
Rated operating voltage: 400 V
Width in number of modular spacings: 36
Modular contactors KM KM20-40M AC IEK
Article: MKK11-20-40
Rated operation current: 20 A
Number of normally open contacts: 4
Rated operating voltage: 400 V
Width in number of modular spacings: 36
Modular contactors KM KM25-22M AC IEK
Article: MKK11-25-22
Rated operation current: 25 A
Number of normally open contacts: 2
Number of normally closed contacts: 2
Rated operating voltage: 400 V
Module contactor KM25-40 AC/DC IEK
Article: MKK20-25-40
Rated operation current: 25 A
Number of normally open contacts: 4
Rated operating voltage: 400 V
Width in number of modular spacings: 54
Total: 33
1 2 3 4
Search by parameters
Rated operation current A
Number of normally open contacts
Rated operating voltage V
Width in number of modular spacings мм
Auxiliary contact interchanges control coil windings, decreasing the holding current by 5 times compared with the start current.
Auxiliary contact interchanges control coil windings, decreasing the holding current by 5 times compared with the start current.
Bridging contact provides high electrical insulation properties.
Bridging contact provides high electrical insulation properties.
Compatibility of sizes allows you to install the contactor in a standard board with any devices of modular series.
Compatibility of sizes allows you to install the contactor in a standard board with any devices of modular series.
Connection terminals allow you to connect the conductors of a cross section from 1 to 25 mm2.
Connection terminals allow you to connect the conductors of a cross section from 1 to 25 mm2.
Contacts are made of silver-containing material, it increases their durability, prolongs the service life and reduces the contact resistance and loss.
Contacts are made of silver-containing material, it increases their durability, prolongs the service life and reduces the contact resistance and loss.
In the control coil circuit a rectifier bridge is mounted that allows to control the 220 VDC coil.
In the control coil circuit a rectifier bridge is mounted that allows to control the 220 VDC coil.
Increased reliability due to the use of stranded conductor for connection of the coil winding.
Increased reliability due to the use of stranded conductor for connection of the coil winding.
Visual indication of the status of main contacts and main technical parameters.
Visual indication of the status of main contacts and main technical parameters.
Contact us Contact us:
+7 (495) 542 22 22
 
Copyright © 1999-2021 IEK. ALL RIGHTS RESERVED.