Description


 

Modular circuit breakers VA47-60 are intended for providing automatic power source cut-off under excess currents.
They are recommended for use in group panels (apartment and floor) and distribution boards of residential, domestic, public and administrative buildings.
64 items per 8 rated currents ranging from 6 to 63 A.

This circuit breaker was awarded a gold medal of the 20th International Exhibition “Electro 2011” in nomination “Best electrical equipment” for high quality characteristics.

Range


Name Rated current In, A Tripping characteristic Bus type Package amount, pcs Product ID
multiple transport
  VA 47-60 1P 6A type 6 12 180 MVA41-1-006-C
VA 47-60 1P 10A type 10 12 180 MVA41-1-010-C
VA 47-60 1P 16A type 16 12 180 MVA41-1-016-C
VA 47-60 1P 25A type 25 12 180 MVA41-1-025-C
VA 47-60 1P 32A type 32 12 180 MVA41-1-032-C
VA 47-60 1P 40A type 40 12 180 MVA41-1-040-C
VA 47-60 1P 50A type 50 12 180 MVA41-1-050-C
VA 47-60 1P 63A type 63 12 180 MVA41-1-063-C
  VA 47-60 2P 6A type 6 6 90 MVA41-2-006-C
VA 47-60 2P 10A type 10 6 90 MVA41-2-010-C
VA 47-60 2P 16A type 16 6 90 MVA41-2-016-C
VA 47-60 2P 25A type 25 6 90 MVA41-2-025-C
VA 47-60 2P 32A type 32 6 90 MVA41-2-032-C
VA 47-60 2 40A type 40 6 90 MVA41-2-040-C
VA 47-60 2P 50A type 50 6 90 MVA41-2-050-C
VA 47-60 2P 63A type 63 6 90 MVA41-2-063-C
  VA 47-60 3P 6A type 6 4 60 MVA41-3-006-C
VA 47-60 3P 10A type 10 4 60 MVA41-3-010-C
VA 47-60 3P 16A type 16 4 60 MVA41-3-016-C
VA 47-60 3P 25A type 25 4 60 MVA41-3-025-C
VA 47-60 3P 32A type 32 4 60 MVA41-3-032-C
VA 47-60 3P 40A type 40 4 60 MVA41-3-040-C
VA 47-60 3P 50A type 50 4 60 MVA41-3-050-C
VA 47-60 3P 63A type 63 4 60 MVA41-3-063-C
  VA 47-60 4P 6A type 6 3 45 MVA41-4-006-C
VA 47-60 4P 10A type 10 3 45 MVA41-4-010-C
VA 47-60 4P 16A type 16 3 45 MVA41-4-016-C
VA 47-60 4P 25A type 25 3 45 MVA41-4-025-C
VA 47-60 4P 32A type 32 3 45 MVA41-4-032-C
VA 47-60 4P 40A type 40 3 45 MVA41-4-040-C
VA 47-60 4P 50A type 50 3 45 MVA41-4-050-C
VA 47-60 4P 63A type 63 3 45 MVA41-4-063-C
  VA 47-60 1P 6A type D 6 D 12 180 MVA41-1-006-D
VA 47-60 1P 10A type D 10 D 12 180 MVA41-1-010-D
VA 47-60 1P 16A type D 16 D 12 180 MVA41-1-016-D
VA 47-60 1P 25A type D 25 D 12 180 MVA41-1-025-D
VA 47-60 1P 32A type D 32 D 12 180 MVA41-1-032-D
VA 47-60 1P 40A type D 40 D 12 180 MVA41-1-040-D
VA 47-60 1P 50A type D 50 D 12 180 MVA41-1-050-D
VA 47-60 1P 63A type D 63 D 12 180 MVA41-1-063-D
  VA 47-60 2P 6A type D 6 D 6 90 MVA41-2-006-D
VA 47-60 2P 10A type D 10 D 6 90 MVA41-2-010-D
VA 47-60 2P 16A type D 16 D 6 90 MVA41-2-016-D
VA 47-60 2P 25A type D 25 D 6 90 MVA41-2-025-D
VA 47-60 2P 32A type D 32 D 6 90 MVA41-2-032-D
VA 47-60 2P 40A type D 40 D 6 90 MVA41-2-040-D
VA 47-60 2P 50A type D 50 D 6 90 MVA41-2-050-D
VA 47-60 2P 63A type D 63 D 6 90 MVA41-2-063-D
  VA 47-60 3P 6A type D 6 D 4 60 MVA41-3-006-D
VA 47-60 3P 10A type D 10 D 4 60 MVA41-3-010-D
VA 47-60 3P 16A type D 16 D 4 60 MVA41-3-016-D
VA 47-60 3P 25A type D 25 D 4 60 MVA41-3-025-D
VA 47-60 3P 32A type D 32 D 4 60 MVA41-3-032-D
VA 47-60 3P 40A type D 40 D 4 60 MVA41-3-040-D
VA 47-60 3P 50A type D 50 D 4 60 MVA41-3-050-D
VA 47-60 3P 63A type D 63 D 4 60 MVA41-3-063-D
  VA 47-60 4P 6A type D 6 D 3 45 MVA41-4-006-D
VA 47-60 4P 10A type D 10 D 3 45 MVA41-4-010-D
VA 47-60 4P 16A type D 16 D 3 45 MVA41-4-016-D
VA 47-60 4P 25A type D 25 D 3 45 MVA41-4-025-D
VA 47-60 4P 32A type D 32 D 3 45 MVA41-4-032-D
VA 47-60 4P 40A type D 40 D 3 45 MVA41-4-040-D
VA 47-60 4P 50A type D 50 D 3 45 MVA41-4-050-D
VA 47-60 4P 63A type D 63 D 3 45 MVA41-4-063-D

Advantages


  • Two types of overcurrent protection – thermal and electromagnetic.
  • Independent contact position indicator.
  • DIN rail latch with a double fixed position.
  • Wide range of operating temperatures from –40 to +50° .
  • Wide engagement lever with improved contact area.
  • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection.

Design Features


  Circuit breaker construction provides for two types of overcurrent protection that can essentially boost the safety of distribution and group systems.   Conducting parts are made of high quality electric copper.
  Updated arc chute allows splitting the electric arc into numerous smaller arcs that contributes to its faster extinguishing.   Welding deposition of silver-bearing composite on the contact block.
  Using buses (PIN, FORK) is possible.   New construction of the trip-free release mechanism (substantially reduced time of contact loss).
  Double quenching grid at the arch chute output raises fire safety preventing combustion products from exposing.   Boosted screw head dimension with cross-functional crest (+,–) helps to facilitate mounting and prevents the screws from falling out during the installation.

Technical Features


Standards GOST R 50345, TU 3421-035-18461115-2010
Rated voltage of 50 Hz (frequency), V 230/400
Rated current, A 6; 10; 16; 25; 32; 40; 50; 63
Rated short-circuit breaking capacity, A 6000
D voltage, V/pole 48
Tripping characteristics , D
NP / No. of poles 1 ÷ 4
Climate type MRC4
Protection degree IP20
Electrical durability, not less than, ops. 6000
Mechanical durability, not less than, ops. 20 000
Cables max. size, mm2 25
Silver content, (Ag), g/pole 0,2
Pole weight, kg 0,2
Ambient temperature range, ° -40 ÷ +50

Standards GOST R 50345, TU 3421-035-18461115-2010
Rated voltage of 50 Hz (frequency), V 230/400
Rated current, 6; 10; 16; 25; 32; 40; 50; 63
Rated short-circuit breaking capacity, A 6000
D voltage, V/pole 48
Tripping characteristics , D
NP / No. of poles 1 ÷ 4
Climate type MRC4
Protection degree IP20
Electrical durability, not less than, ops. 6000
Mechanical durability, not less than, ops. 20 000
Cables max. size, mm2 25
Silver content, (Ag), g/pole 0,2
Pole weight, kg 0,2
Ambient temperature range, ° -40 ÷ +50