Description


 

Modular circuit breakers VA47-29 are intended for protecting distribution and group systems having different loads.
Modular circuit breakers VA47-29 are recommended for use in electrical distribution panels of residential and public buildings as well as in industries.
27 items per 9 rated currents ranging from 6 to 63 A.

This circuit breaker was awarded a gold medal of the 15th International Exhibition “Electro 2006” in nomination “Best electrical equipment” for the solution ensuring electric security of residential buildings and industries as well as high performance and economic characteristics.

Range


Name Rated current In, A Tripping characteristic Bus type Package amount, pcs Product ID
multiple transport
  VA47-29 1P 1,6A 4,5 type B 1,6 B 12 144 MVA21-1-D16-B
VA47-29 1P 2,5A 4,5 type B 2,5 B 12 144 MVA21-1-D25-B
VA47-29 1P 6A 4,5 type C 6 C 12 144 MVA21-1-006-C
VA47-29 1P 10A 4,5 type C 10 C 12 144 MVA21-1-010-C
VA47-29 1P 16A 4,5 type C 16 C 12 144 MVA21-1-016-C
VA47-29 1P 20A 4,5 type C 20 C 12 144 MVA21-1-020-C
VA47-29 1P 25A 4,5 type C 25 C 12 144 MVA21-1-025-C
VA47-29 1P 32A 4,5 type C 32 C 12 144 MVA21-1-032-C
VA47-29 1P 40A 4,5 type C 40 C 12 144 MVA21-1-040-C
VA47-29 1P 50A 4,5 type C 50 C 12 144 MVA21-1-050-C
VA47-29 1P 63A 4,5 type C 63 C 12 144 MVA21-1-063-C
VA47-29 1P 1A 4,5 type D 1 D 12 144 MVA21-1-001-D
VA47-29 1P 1,6A 4,5 type D 1,6 D 12 144 MVA21-1-D16-D
VA47-29 1P 2,5A 4,5 type D 2,5 D 12 144 MVA21-1-D25-D
VA47-29 1P 8A 4,5 type D 8 D 12 144 MVA21-1-008-D
VA47-29 1P 13A 4,5 type D 13 D 12 144 MVA21-1-013-D
  VA47-29 2P 2A 4,5 type B 2 B 6 72 MVA21-2-002-B
VA47-29 2P 4A 4,5 type B 4 B 6 72 MVA21-2-004-B
VA47-29 2P 6A 4,5 type B 6 B 6 72 MVA21-2-006-B
VA47-29 2P 13A 4,5 type B 13 B 6 72 MVA21-2-013-B
VA47-29 2P 6A 4,5 type C 6 C 6 72 MVA21-2-006-C
VA47-29 2P 10A 4,5 type C 10 C 6 72 MVA21-2-010-C
VA47-29 2P 16A 4,5 type C 16 C 6 72 MVA21-2-016-C
VA47-29 2P 20A 4,5 type C 20 C 6 72 MVA21-2-020-C
VA47-29 2P 25A 4,5 type C 25 C 6 72 MVA21-2-025-C
VA47-29 2P 32A 4,5 type C 32 C 6 72 MVA21-2-032-C
VA47-29 2P 40A 4,5 type C 40 C 6 72 MVA21-2-040-C
VA47-29 2P 50A 4,5 type C 50 C 6 72 MVA21-2-050-C
VA47-29 2P 63A 4,5 type C 63 C 6 72 MVA21-2-063-C
VA47-29 2P 5A 4,5 type D 5 D 6 72 MVA21-2-005-D
VA47-29 2P 13A 4,5 type D 13 D 6 72 MVA21-2-013-D
VA47-29 2P 20A 4,5 type D 20 D 6 72 MVA21-2-020-D
VA47-29 2P 32A 4,5 type D 32 D 6 72 MVA21-2-032-D
VA47-29 2P 50A 4,5 type D 50 D 6 72 MVA21-2-050-D
VA47-29 2P 63A 4,5 type D 63 D 6 72 MVA21-2-063-D
  VA47-29 3P 1A 4,5 type B 1 B 4 48 MVA21-3-001-B
VA47-29 3P 13A 4,5 type B 13 B 4 48 MVA21-3-013-B
VA47-29 3P 20A 4,5 type B 20 B 4 48 MVA21-3-020-B
VA47-29 3P 6A 4,5 type C 6 C 4 48 MVA21-3-006-C
VA47-29 3P 10A 4,5 type C 10 C 4 48 MVA21-3-010-C
VA47-29 3P 16A 4,5 type C 16 C 4 48 MVA21-3-016-C
VA47-29 3P 20A 4,5 type C 20 C 4 48 MVA21-3-020-C
VA47-29 3P 25A 4,5 type C 25 C 4 48 MVA21-3-025-C
VA47-29 3P 32A 4,5 type C 32 C 4 48 MVA21-3-032-C
VA47-29 3P 40A 4,5 type C 40 C 4 48 MVA21-3-040-C
VA47-29 3P 50A 4,5 type C 50 C 4 48 MVA21-3-050-C
VA47-29 3P 63A 4,5 type C 63 C 4 48 MVA21-3-063-C
  VA47-29 4P 25A 4,5 type B 25 B 3 36 MVA21-4-025-B
VA47-29 4P 50A 4,5 type B 50 B 3 36 MVA21-4-050-B
VA47-29 4P 63A 4,5 type B 63 B 3 36 MVA21-4-063-B
VA47-29 4P 1A 4,5 type C 1 C 3 36 MVA21-4-001-C
VA47-29 4P 2A 4,5 type C 2 C 3 36 MVA21-4-002-C
VA47-29 4P 3A 4,5 type C 3 C 3 36 MVA21-4-003-C
VA47-29 4P 4A 4,5 type C 4 C 3 36 MVA21-4-004-C
VA47-29 4P 5A 4,5 type C 5 C 3 36 MVA21-4-005-C
VA47-29 4P 6A 4,5 type C 6 C 3 36 MVA21-4-006-C
VA47-29 4P 8A 4,5 type C 8 C 3 36 MVA21-4-008-C
VA47-29 4P 10A 4,5 type C 10 C 3 36 MVA21-4-010-C
VA47-29 4P 13A 4,5 type C 13 C 3 36 MVA21-4-013-C
VA47-29 4P 16A 4,5 type C 16 C 3 36 MVA21-4-016-C
VA47-29 4P 20A 4,5 type C 20 C 3 36 MVA21-4-020-C
VA47-29 4P 25A 4,5 type C 25 C 3 36 MVA21-4-025-C
VA47-29 4P 32A 4,5 type C 32 C 3 36 MVA21-4-032-C
VA47-29 4P 40A 4,5 type C 40 C 3 36 MVA21-4-040-C
VA47-29 4P 50A 4,5 type C 50 C 3 36 MVA21-4-050-C
VA47-29 4P 63A 4,5 type C 63 C 3 36 MVA21-4-063-C
VA47-29 4P 1A 4,5 type D 1 D 3 36 MVA21-4-001-D
VA47-29 4P 3A 4,5 type D 3 D 3 36 MVA21-4-003-D
VA47-29 4P 4A 4,5 type D 4 D 3 36 MVA21-4-004-D
VA47-29 4P 6A 4,5 type D 6 D 3 36 MVA21-4-006-D
VA47-29 4P 13A 4,5 type D 13 D 3 36 MVA21-4-013-D
VA47-29 4P 16A 4,5 type D 16 D 3 36 MVA21-4-016-D
VA47-29 4P 25A 4,5 type D 25 D 3 36 MVA21-4-025-D
VA47-29 4P 32A 4,5 type D 32 D 3 36 MVA21-4-032-D
VA47-29 4P 40A 4,5 type D 40 D 3 36 MVA21-4-040-D
VA47-29 4P 50A 4,5 type D 50 D 3 36 MVA21-4-050-D
VA47-29 4P 63A 4,5 type D 63 D 3 36 MVA21-4-063-D

Advantages


  • Two types of short circuit and overload protection.
  • Complete set of supplementary devices with the possibility of simple independent installation:
    • Status contact KS47;
    • Status contact KSV47;
    • Undervoltage release RMM47;
    • Shunt trip RN47.
  • Special casing construction with boosted heat dissipation.
  • Independent contact position indicator.
  • DIN rail latch with a double fixed position.
  • Wide range of operating temperatures from –40 to +50° .
  • Updated wider engagement lever with improved contact area.
  • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection.

Design Features


  Circuit breaker construction provides two types of overload and short circuit protection that can essentially boost the safety of distribution and group systems.   Connecting a bus to the circuit breaker provides for ensuring two or three-wire connection.
  Unified casing with the possibility to connect supplementary devices does not require disassembling. Independent installation is possible.   Main circuit status indicator provides exact information on the contacts status independently from lever position.
  Boosted screw head dimension with cross-functional crest (+,–) helps to facilitate mounting and prevents the screws from falling out during the installation.   Welding deposition of silver-bearing composite boosts the contact block’s wear-resistance and lowers the transient one.
  Plexiglas fitting protects the thermal cut-off mechanism from the factory settings changing.   Updated wider engagement lever with improved contact area facilitates commutation process.
  Special casing construction with boosted heat dissipation allows raising the output capacity per 10%.   Notches on terminal clamps allow lowering thermal losses and boosting the mechanical stability of connection.

Technical Features


Standards GOST R 50345-99, TU 2000 AGIE.641.235.003
Rated voltage of 50 Hz (frequency), V 230/400
Rated current In, A 6; 10; 16; 20; 25; 32; 40; 50; 63
Rated short-circuit breaking capacity, A 4500
D voltage, V/pole 48
Tripping characteristics
NP / No. of poles 1, 2, 3
Climate type MRC4
Protection degree IP20
Electrical durability, not less than, ops. 6000
Mechanical durability, not less than, ops. 20 000
Cables max. size, mm2 25
Silver content, (Ag), g/pole 0,5
Pole weight, kg 0,11
Ambient temperature range, ° -40 ÷ +50

Standards GOST R 50345-99, TU 2000 AGIE.641.235.003
Rated voltage of 50 Hz (frequency), V 230/400
Rated current In, A 6; 10; 16; 20; 25; 32; 40; 50; 63
Rated short-circuit breaking capacity, A 4500
D voltage, V/pole 48
Tripping characteristics
NP / No. of poles 1, 2, 3
Climate type MRC4
Protection degree IP20
Electrical durability, not less than, ops 6000
Mechanical durability, not less than, ops. 20 000
Cables max. size, mm2 25
Silver content, (Ag), g/pole 0,5
Pole weight, kg 0,11
Ambient temperature range, ° -40 ÷ +50