IEK
RSS Русский English Казахский Español Feedback Sitemap
Products catalog
Pricelist

05.07.01.01.01 Cable stubs with paper isolation 1kV

  • Description
  • Assortment
  • Design
    features
  • Package bundle
KV(N)tp-1 heat-shrink sleeve is designed for termination of aluminum or copper conductors of cables with impregnated-paper insulation for voltages up to 1kV: AAG-1, AASh-1, AAB-1, AAP-1, AABSh-1, AAPSh-1, ASG-1, AASSh-1, ASBSh-1, SG-1, SSh-1, SBSh-1, SB-1, SP-1, SK-1, SBG-1, SPG -1, their equivalents and versions.
Sorting: article name
Total: 24 Go to page: 1 2 3
Cable stub KV(N)tp 3x150/240 with paper isolation 1kV IEK
Article: UZM-BIK1-NVN3-150240XZ
Nominal cross section: 150...240 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x150/240 with paper isolation 1kV IEK
Article: UZM-BIK1-NVN3-150240SP
Nominal cross section: 150...240 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x150/240 with paper isolation 1kV IEK
Article: UZM-BIK1-NVN3-150240SZ
Nominal cross section: 150...240 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x16/25 with paper isolation 1kW IEK
Article: UZM-BIK1-NVN3-1625XZ
Nominal cross section: 16...25 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x16/25 with paper isolation 1kW IEK
Article: UZM-BIK1-NVN3-1625SP
Nominal cross section: 16...25 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x16/25 with paper isolation 1kW IEK
Article: UZM-BIK1-NVN3-1625SZ
Nominal cross section: 16...25 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x35/50 with paper isolation 1kV IEK
Article: UZM-BIK1-NVN3-3550XZ
Nominal cross section: 35...50 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x35/50 with paper isolation 1kV IEK
Article: UZM-BIK1-NVN3-3550SP
Nominal cross section: 35...50 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x35/50 with paper isolation 1kV IEK
Article: UZM-BIK1-NVN3-3550SZ
Nominal cross section: 35...50 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub KV(N)tp 3x70/120 with paper isolation 1kV IEK
Article: UZM-BIK1-NVN3-70120XZ
Nominal cross section: 70...120 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Total: 24
1 2 3
Search by parameters
Nominal cross section mm²
Number of cores wiring
Oil-resistant tubes placed over the phase insulation of cable strands.
Oil-resistant tubes placed over the phase insulation of cable strands.
Special sealant of hydraulic and chemical protection is laid over the grounding unit of cable sheath and armor.
Special sealant of hydraulic and chemical protection is laid over the grounding unit of cable sheath and armor.
The set of cable sheath and armor grounding is available for order with materials for soldering or with constant pressure springs made of high quality stainless steel with high content of chromium and nickel.
The set of cable sheath and armor grounding is available for order with materials for soldering or with constant pressure springs made of high quality stainless steel with high content of chromium and nickel.
Two-layer heat-shrinkable materials with adhesive hot-melt glue layer on the inner surface of the tubes and gloves.
Two-layer heat-shrinkable materials with adhesive hot-melt glue layer on the inner surface of the tubes and gloves.
Contact us Contact us:
+7 (495) 542 22 22
 
Copyright © 1999-2021 IEK. ALL RIGHTS RESERVED.