IEK
RSS Русский English Казахский Español Feedback Sitemap
Products catalog
Pricelist

05.07.01.01.02.02 Outside terminal for cable with PVC / SPE insulation with armor up to 1 kV

  • Description
  • Assortment
  • Design
    features
  • Package bundle
KV(N)tp-1 heat-shrink sleeve is designed for termination of aluminum or copper conductors of cables with impregnated-paper insulation for voltages up to 1kV: AAG-1, AASh-1, AAB-1, AAP-1, AABSh-1, AAPSh-1, ASG-1, AASSh-1, ASBSh-1, SG-1, SSh-1, SBSh-1, SB-1, SP-1, SK-1, SBG-1, SPG -1, their equivalents and versions.
Sorting: article name
Total: 36 Go to page: 1 2 3 4
Cable stub PKVtpbe 1x150/240 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN1-150240SZ
Nominal cross section: 150...240 mm²
Number of cores wiring: 1
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 1x16/25 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN1-1625SZ
Nominal cross section: 16...25 mm²
Number of cores wiring: 1
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 1x35/50 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN1-3550SZ
Nominal cross section: 35...50 mm²
Number of cores wiring: 1
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 1x70/120 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN1-70120SZ
Nominal cross section: 70...120 mm²
Number of cores wiring: 1
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 2x150/240 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN2-150240SZ
Nominal cross section: 150...240 mm²
Number of cores wiring: 2
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 2x16/25 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN2-1625SZ
Nominal cross section: 16...25 mm²
Number of cores wiring: 2
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 2x35/50 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN2-3550SZ
Nominal cross section: 35...50 mm²
Number of cores wiring: 2
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 2x70/120 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN2-70120SZ
Nominal cross section: 70...120 mm²
Number of cores wiring: 2
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 3x150/240 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN3-150240SZ
Nominal cross section: 150...240 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Cable stub PKVtpbe 3x16/25 with PVC isolation 1kV IEK
Article: UZM-XLBK1-NVN3-1625SZ
Nominal cross section: 16...25 mm²
Number of cores wiring: 3
Nominal voltage: 1 kV
Мин температура полной усадки: 120 °C
Total: 36
1 2 3 4
Search by parameters
Nominal cross section mm²
Number of cores wiring
It is suitable for armored and shielded cables, it includes an optional set of soldered or solderless grounding.
It is suitable for armored and shielded cables, it includes an optional set of soldered or solderless grounding.
The set of cable sheath and armor grounding is available for order with materials for soldering or with constant pressure springs made of high quality stainless steel with high content of chromium and nickel.
The set of cable sheath and armor grounding is available for order with materials for soldering or with constant pressure springs made of high quality stainless steel with high content of chromium and nickel.
Two-layer heat-shrinkable materials with adhesive hot-melt glue layer on the inner surface of the tubes and gloves.
Two-layer heat-shrinkable materials with adhesive hot-melt glue layer on the inner surface of the tubes and gloves.
Contact us Contact us:
+7 (495) 542 22 22
 